Table 1 below gives the values and description of the codes that can be adjust, depending on the eggs that are placed inside.

 If a condition set by a code is not met, then the controller signals to the user by flashing the LED "ALARM" . There is an option for an audible alarm..

 

Code

Function

Range

Note

Factory Default

P0

High temperature warning.

0 ~ 75

  Warning only

38.7

P1

Exhaust temperature limit

0 ~ 75

  Cooling exhaust starts

38.2

P2

Exhaustion temperature low limit

0 ~ 75

  Stop cooling exhaust

38.0

P3

Main temperature up limit

0 ~ 75

Main heater stops heating

38.0

P4

Main temperature low limit

0 ~ 75

Main heater starts heating

37.9

P5

Aux temperature up limit

0 ~ 75

Aux heater stops heating

37.7

P6

Aux temperature low limit

0 ~ 75

Aux heater starts heating

37.5

P7

Low temperature warning point

0 ~ 75

 

37.2

P8

High humidity warning point

0 ~ 99%

 

70

P9

Humidity up limit

0 ~ 99%

Humidify load stops humidifying

60

Pb

Humidity low limit

0 ~ 99%

Humidify load starts humidifying

55

Pc

Exhaustion humidity up limit

0 ~ 99%

Start ventilation for de-humidifying

65

Pd

Exhaustion humidity low limit

0 ~ 99%

Stop de-humidifying ventilation

60

PE

Over wet exhaustion protection

0/1

0: disable; 1: enable

0

PP

Low humidity warning point

0 ~ 99%

 

50

                                                                                    Table 1

 

 

Code

Function

Range

Note

Factory Default

F1

Egg turn period

1 ~ 999 min

 

90

F2

Egg turn time

0 ~ 999 sec

0: no egg turning function

180

F3

Egg turn times

0 ~ 999 times

0: turn for ever

0

F4

Air exhausting period

1 ~ 999 min

 

120

F5

Air exhausting time

0 ~ 999 sec

0: no air exhausting

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F6

Temperature calibration

-9.9 ~ 9.9

 

0.0

F7

Humidity calibration

-20 ~ 20%

 

0

F8

Illumination period

1 ~ 999 min

 

90

F9

Illumination time

0 ~ 999 min

0: no illuminating function

0

FF

Incubated days

0 ~ 99 day

Only clear operation

0

 

 

Date of last revision 24-May-21