Code |
Function |
Range |
Note |
Factory
Default |
P0 |
High temperature warning. |
0 ~
75℃ |
Warning only |
38.7 |
P1 |
Exhaust
temperature limit |
0 ~
75℃ |
Cooling exhaust starts |
38.2 |
P2 |
Exhaustion
temperature
low
limit |
0 ~
75℃ |
Stop
cooling exhaust |
38.0 |
P3 |
Main
temperature
up
limit |
0 ~
75℃ |
Main
heater
stops
heating |
38.0 |
P4 |
Main
temperature
low
limit |
0 ~
75℃ |
Main
heater
starts
heating |
37.9 |
P5 |
Aux
temperature
up
limit |
0 ~
75℃ |
Aux
heater
stops
heating |
37.7 |
P6 |
Aux
temperature
low
limit |
0 ~
75℃ |
Aux
heater
starts
heating |
37.5 |
P7 |
Low
temperature
warning
point |
0 ~
75℃ |
|
37.2 |
P8 |
High
humidity
warning
point |
0 ~
99% |
|
70 |
P9 |
Humidity
up
limit |
0 ~
99% |
Humidify
load
stops
humidifying |
60 |
Pb |
Humidity
low
limit |
0 ~
99% |
Humidify
load
starts
humidifying |
55 |
Pc |
Exhaustion
humidity
up
limit |
0 ~
99% |
Start
ventilation
for
de-humidifying |
65 |
Pd |
Exhaustion
humidity
low
limit |
0 ~
99% |
Stop
de-humidifying
ventilation |
60 |
PE |
Over
wet
exhaustion
protection |
0/1 |
0:
disable;
1:
enable |
0 |
PP |
Low
humidity
warning
point |
0 ~
99% |
|
50 |